 "answer": "In the Village of Three Rivers, New Brunswick, fences & pool enclosures rules are set by Community of Three Rivers Rural Plan By-law No. 2026-09, verified 2026-09-27. A permit is required. Max height front: 1 metre. Max height rear side: 2 m in a Residential zone; 2.5 m in any other zone.",
 "municipality_id": "gx-003113",
 "municipality": "Three Rivers",
 "status_type": "Village",
 "jurisdiction": "New Brunswick",
 "country": "CA",
 "topic": "fences",
 "label": "Fences & pool enclosures",
 "status": "found",
 "last_verified": "2026-09-27",
 "official_website": "https://threeriversnb.ca/",
 "documents": [
  {
   "primary": true,
   "is_official": true,
   "title": "Community of Three Rivers Rural Plan By-law No. 2026-09",
   "category": "fences",
   "document_type": "bylaw",
   "status": "adopted",
   "adopted_date": null,
   "document_url": "https://plan360.ca/media-planning/library/TR-RP-No._2026-09_registered_2026-05-01_.pdf",
   "summary": "Fences capped at 1m in the required front yard, 2m elsewhere in Residential zones (2.5m in other zones); corner-lot/railway-crossing sight triangles bar fences/hedges/trees over 0.6m within 4.6m of the intersection; pools over 0.91m deep need a 1.5m fence enclosure with a self-latching gate.",
   "discovered_by": "nb-newcats",
   "discovered_at": "2026-09-27",
   "capture_sha256": "6c4c8eed890ca0b625c5f5abbcf1f601a34f67c51483bc0972abe52c9faa2fc9",
   "captured_at": "2026-09-28T01:03:51+00:00",
   "capture_http_status": 200,
   "document_number": "2026-09",
   "snapshot_url": "https://pub-e61c5ee2a8704225bfa8de0c280e8a2c.r2.dev/bylaws/6c4c8eed890ca0b625c5f5abbcf1f601a34f67c51483bc0972abe52c9faa2fc9.pdf",
   "link_dead": false,
   "facts": {
    "max_height_rear_side": "2 m in a Residential zone; 2.5 m in any other zone",
    "max_height_front": "1 metre",
    "permit_required": true,
    "pool_enclosure": "Enclosure at least 1.5 m high; gates self-closing with self-latching device at least 1.3 m above bottom.",
    "sight_triangle": "On a corner lot or lot abutting a railway crossing, no fence/sign/hedge/shrub/bush/tree/structure/building more than 0.6 m above grade within triangular area 4.6 m from street intersection.",
    "prohibited_materials": "Electrified, barbed wire, or other dangerous material prohibited, except RA/RD/IRD along abutting lot line."
   },
   "fact_citations": {
    "max_height_rear_side": "s. 3.15.1(b)",
    "max_height_front": "s. 3.15.1(a)",
    "permit_required": "s. 2.9.1; s. 2.9.5(c)",
    "pool_enclosure": "s. 3.18.1; s. 3.18.6(c)",
    "sight_triangle": "s. 3.12",
    "prohibited_materials": "s. 3.15.2"
   },
   "transcript_url": "/ca/nb/three-rivers/fences/plan-2026-09/",
   "transcript_quality": "exact"
  }
 ],
 "source": "https://govanswers.org/ca/nb/three-rivers/fences/"
}