{
 "answer": "In the City of Charlottetown, Prince Edward Island, fences & pool enclosures rules are set by City of Charlottetown Zoning & Development Bylaw (2018-11), verified 2026-09-27. Max height front: 1.0 m (3.3 ft) in 500 Lot Area; 2.50 m (8.2 ft) in Employment/Industrial Zones; 1.83 m (6.0 ft) in any other Zone. Max height rear side: 2.5 m (8.2 ft). Prohibited materials: Except active farm, no Fence may be electrified or incorporate barbed wire or other dangerous material.",
 "municipality_id": "gx-003182",
 "municipality": "Charlottetown",
 "status_type": "City",
 "jurisdiction": "Prince Edward Island",
 "country": "CA",
 "topic": "fences",
 "label": "Fences & pool enclosures",
 "status": "found",
 "last_verified": "2026-09-27",
 "official_website": "https://charlottetown.ca/",
 "documents": [
  {
   "primary": true,
   "is_official": true,
   "title": "City of Charlottetown Zoning & Development Bylaw (2018-11)",
   "category": "fences",
   "document_type": "bylaw",
   "status": "adopted",
   "adopted_date": "2018-10-01",
   "document_url": "https://irac.pe.ca/infocentre/documents/LA20003-City%20Zoning%20and%20Dev%20Bylaw.pdf",
   "summary": "Max fence height 2.5 m in any zone; in front/flankage yards 1.0 m in the 500 Lot Area, 2.5 m in Employment/Industrial zones and 1.83 m elsewhere (4.4). No electrified or barbed-wire fences except on active farms. Swimming pools must be fully surrounded by a fence at least 1.83 m high that impedes passage (4.3). Corner-lot sight triangle: no structures",
   "discovered_by": "pe-newcats",
   "discovered_at": "2026-09-27",
   "capture_sha256": "a0e4f720533338a5c2e26ea5656554b985f0847ec72d2cf7977b079d99e83a48",
   "captured_at": "2026-09-28T01:08:46+00:00",
   "capture_http_status": 200,
   "document_number": "2018-11",
   "snapshot_url": "https://pub-e61c5ee2a8704225bfa8de0c280e8a2c.r2.dev/bylaws/a0e4f720533338a5c2e26ea5656554b985f0847ec72d2cf7977b079d99e83a48.pdf",
   "link_dead": false,
   "facts": {
    "max_height_rear_side": "2.5 m (8.2 ft)",
    "max_height_front": "1.0 m (3.3 ft) in 500 Lot Area; 2.50 m (8.2 ft) in Employment/Industrial Zones; 1.83 m (6.0 ft) in any other Zone",
    "permit_required": false,
    "pool_enclosure": "Swimming Pool shall be completely surrounded with a Fence or Structure not less than 1.83 m (6.0 ft) in Height that impedes unauthorized passage through, under, or over.",
    "sight_triangle": "No Building or Structure within 6 m (19.7 ft) of triangular space between Street Lot Lines; no Structures or vegetation over 1.0 m (3.3 ft) where it may obstruct view within 6 m (19.7 ft) of intersection.",
    "prohibited_materials": "Except active farm, no Fence may be electrified or incorporate barbed wire or other dangerous material."
   },
   "fact_citations": {
    "max_height_rear_side": "s. 4.4.2",
    "max_height_front": "s. 4.4.2(a)-(c)",
    "permit_required": "s. 3.2.1",
    "pool_enclosure": "s. 4.3.2",
    "sight_triangle": "s. 4.10.1 and s. 4.10.2",
    "prohibited_materials": "s. 4.4.3"
   },
   "transcript_url": "/ca/pe/charlottetown/fences/bylaw-2018-11/",
   "transcript_quality": "exact"
  }
 ],
 "source": "https://govanswers.org/ca/pe/charlottetown/fences/"
}